Water Jet:
A DTS chiller will maintain proper cutting water temperature
and reduce the potential for costly pump rebuilds.
DTS offers
two options for
water jet
cooling, the closed loop chiller and the
inline which is environmentally friendly by reducing 70-80%
water consumption and sewage cost. Many
times savings
in operational costs realized from a closed loop system can
support the purchase of the chiller.
Two types of pumps to be cooled:
•Direct
Drive
ØPiston
Driven
ØFlow
through chillers
•Intensifier
Pumps
ØHydraulic
cooling required
ØClosed
loop chiller
Sizing Information
- Typical water usage
- BTU/Required or specification sheet (chart below)
| Company |
Pump Type |
HP |
BTU/HR |
Chiller Model |
Chiller Type |
| Omax |
Direct Drive |
20 |
24,000 |
HAF2000 |
Flow Through |
| Omax |
Direct Drive |
30 |
24,000 |
HAF2000 |
Flow Through |
| Omax |
Direct Drive |
40 |
36,000 |
HAF3000 |
Flow Through |
| Jetedge |
Intensifier |
30 |
22,000 |
200AC |
Closed Loop |
| Jetedge |
Intensifier |
50 |
40,000 |
500AC |
Closed Loop |
| Jetedge |
Intensifier |
75 |
65,000 |
750AC |
Closed Loop |
| Jetedge |
Intensifier |
100 |
95,000 |
750AC |
Closed Loop |
| Jetedge |
Intensifier |
150 |
125,000 |
1001AC |
Closed Loop |
| Jetedge |
Intensifier |
200 |
175,000 |
1500AC |
Closed Loop |
| Flow |
Direct Drive |
11-Cougar |
18,000 |
HAF2000 |
Flow Through |
| Flow |
Direct Drive |
25-Cougar |
18,000 |
HAF2000 |
Flow Through |
| Flow |
Direct Drive |
30-Eagle |
24,000 |
HAF2000 |
Flow Through |
| Flow |
Direct Drive |
50-Eagle |
24,000 |
HAF2000 |
Flow Through |
| Flow |
Direct Drive |
30-Hyplex |
24,000 |
HAF2000 |
Flow Through |
| Flow |
Direct Drive |
50-Hyplex |
36,000 |
HAF3000 |
Flow Through |
| Flow |
Intensifier |
25 - 5X |
36,000 |
300AC |
Closed Loop |
| Flow |
Intensifier |
25 - 6XS |
36,000 |
300AC |
Closed Loop |
| Flow |
Intensifier |
40 - 9XS |
36,000 |
300AC |
Closed Loop |
| Flow |
Intensifier |
40 - 9XD |
36,000 |
300AC |
Closed Loop |
| Flow |
Intensifier |
40- 11XS |
36,000 |
300AC |
Closed Loop |
| Flow |
Intensifier |
50 - 7XS |
36,000 |
300AC |
Closed Loop |
| Flow |
Intensifier |
50 - 20XS |
60,000 |
500AC |
Closed Loop |
| Flow |
Intensifier |
60 - 7XD |
60,000 |
500AC |
Closed Loop |
| Flow |
Intensifier |
60- 11XD |
60,000 |
500AC |
Closed Loop |
| Flow |
Intensifier |
100 - 12XD |
60,000 |
500AC |
Closed Loop |
| Flow |
Intensifier |
100 - 20XD |
90,000 |
750AC |
Closed Loop |
| Flow |
Intensifier |
150 - 25XT |
120,000 |
1001AC |
Closed Loop |
| KMT |
Intensifier |
30 |
18,000 |
200AC |
Closed Loop |
| KMT |
Intensifier |
50 |
24,000 |
200AC |
Closed Loop |
| KMT |
Intensifier |
60 |
36,000 |
300AC |
Closed Loop |
| KMT |
Intensifier |
75 |
36,000 |
300AC |
Closed Loop |
| KMT |
Intensifier |
100 |
60,000 |
500AC |
Closed Loop |
| WSI |
Intensifier |
15 |
12,000 |
100AC |
Closed Loop |
| WSI |
Intensifier |
30 |
18,000 |
200AC |
Closed Loop |
| WSI |
Intensifier |
50 |
36,000 |
300AC |
Closed Loop |
| WSI |
Intensifier |
100 |
88,000 |
750AC |
Closed Loop |
| Bohler |
Intensifier |
48 |
36,000 |
300AC |
Closed Loop |
| Bohler |
Intensifier |
96 |
96,000 |
750AC |
Closed Loop |
|