Water Jet:
A DTS chiller will maintain proper cutting water temperature and reduce the potential for costly pump rebuilds. DTS offers two options for water jet cooling, the inline and the environmentally friendly closed loop option. The closed loop option reduces water consumption and sewage cost. Often the savings in operational costs realized will support the purchase of the chiller.
Types of pumps to be cooled:
-
Direct Drive
-
Intensifier Pumps
| Company |
Pump Type |
HP |
BTU/HR |
Chiller Model |
Chiller Type |
| Omax |
Direct Drive |
20 |
24,000 |
AVI-2000-M |
Flow Through |
| Omax |
Direct Drive |
30 |
24,000 |
AVI-2000-M |
Flow Through |
| Omax |
Direct Drive |
40 |
36,000 |
AVI-3000-M |
Flow Through |
| Jetedge |
Intensifier |
30 |
22,000 |
SVI-2000-M |
Closed Loop |
| Jetedge |
Intensifier |
50 |
40,000 |
SVI-5000-M |
Closed Loop |
| Jetedge |
Intensifier |
75 |
65,000 |
SVI-7500-M |
Closed Loop |
| Jetedge |
Intensifier |
100 |
95,000 |
SVI-7500-M
|
Closed Loop |
| Jetedge |
Intensifier |
150 |
125,000 |
SVI-10000-M |
Closed Loop |
| Jetedge |
Intensifier |
200 |
175,000 |
SVI-15000-M |
Closed Loop |
| Flow |
Direct Drive |
11-Cougar |
18,000 |
AVI-2000-M
|
Flow Through |
| Flow |
Direct Drive |
25-Cougar |
18,000 |
AVI-2000-M
|
Flow Through |
| Flow |
Direct Drive |
30-Eagle |
24,000 |
AVI-2000-M
|
Flow Through |
| Flow |
Direct Drive |
50-Eagle |
24,000 |
AVI-2000-M
|
Flow Through |
| Flow |
Direct Drive |
30-Hyplex |
24,000 |
AVI-2000-M
|
Flow Through |
| Flow |
Direct Drive |
50-Hyplex |
36,000 |
AVI-3000-M
|
Flow Through |
| Flow |
Intensifier |
25 - 5X |
36,000 |
SVI-3000-M |
Closed Loop |
| Flow |
Intensifier |
25 - 6XS |
36,000 |
SVI-3000-M
|
Closed Loop |
| Flow |
Intensifier |
40 - 9XS |
36,000 |
SVI-3000-M
|
Closed Loop |
| Flow |
Intensifier |
40 - 9XD |
36,000 |
SVI-3000-M
|
Closed Loop |
| Flow |
Intensifier |
40- 11XS |
36,000 |
SVI-3000-M
|
Closed Loop |
| Flow |
Intensifier |
50 - 7XS |
36,000 |
SVI-3000-M
|
Closed Loop |
| Flow |
Intensifier |
50 - 20XS |
60,000 |
SVI-5000-M
|
Closed Loop |
| Flow |
Intensifier |
60 - 7XD |
60,000 |
SVI-5000-M
|
Closed Loop |
| Flow |
Intensifier |
60- 11XD |
60,000 |
SVI-5000-M
|
Closed Loop |
| Flow |
Intensifier |
100 - 12XD |
60,000 |
SVI-5000-M
|
Closed Loop |
| Flow |
Intensifier |
100 - 20XD |
90,000 |
SVI-7500-M
|
Closed Loop |
| Flow |
Intensifier |
150 - 25XT |
120,000 |
SVI-10000-M
|
Closed Loop |
| KMT |
Intensifier |
30 |
18,000 |
SVI-2000-M
|
Closed Loop |
| KMT |
Intensifier |
50 |
24,000 |
SVI-2000-M
|
Closed Loop |
| KMT |
Intensifier |
60 |
36,000 |
SVI-3000-M
|
Closed Loop |
| KMT |
Intensifier |
75 |
36,000 |
SVI-3000-M
|
Closed Loop |
| KMT |
Intensifier |
100 |
60,000 |
SVI-5000-M
|
Closed Loop |
| WSI |
Intensifier |
15 |
12,000 |
JHI-1000-CE-M |
Closed Loop |
| WSI |
Intensifier |
30 |
18,000 |
SVI-2000-M
|
Closed Loop |
| WSI |
Intensifier |
50 |
36,000 |
SVI-3000-M
|
Closed Loop |
| WSI |
Intensifier |
100 |
88,000 |
SVI-7500-M
|
Closed Loop |
| Bohler |
Intensifier |
48 |
36,000 |
SVI-3000-M |
Closed Loop |
| Bohler |
Intensifier |
96 |
96,000 |
SVI-7500-M
|
Closed Loop |
Sizing Information